Free Ground Shipping on pre-paid orders over $600

IRIS Performance Specifications





PERFORMANCE SPECIFICATIONS

SPECIFICATION

PARAMETER

RANGE

Insertion Loss

Single-Mode (9/125um)

0.35dB – Typical, 0.50dB – Maximum

Temperature

Operational

-46ºC to 85ºC

Temperature

Storage

-62ºC to 85ºC

Cable Retention1

TlA-455-6

200lbs. for 10 minutes

Cable Seal Flexing

TlA/ElA-455-1

Procedure l

Twist

ElA-455-36

100 cycles,±90º

Mating Durability

ElA-455-21

500 cycles

Impact2

TlA/ElA-455-2

Method B, 8 drops

Vibration

TlA/ElA-455-11C

Condition C, 1.5 hr/axis

Mechanical Shock

TlA-455-14

Condition C, 5 shocks/axis

Thermal Shock

TlA/455-71

Schedule C, -62ºC 85ºC, 5 cycles

Temperature Humidity Cycling

TlA/ElA-455-4

65ºC at 95% RH

Life Aging

ElA/TlA-455-11

85ºC, 250 hours

Water Pressure

TlA-455-98

Method A, Prod. A, 1M-24 hours

Sand and Dust

ElA/TIA-455-35

16 Hours

Salt Spray

TlA-455-16

Condition C, 250 hours

 

Notes:

1.     When tested with military-rated fiber optic cable

2.     Plug, Receptacle tested open ended